TECHNICAL SUMMARY (Vật liệu chuyên dùng & ứng dụng lọc khí)
Honeycomb activated carbon Vietnam supplied by Xuyen Viet Environmental Co., Ltd. is available in extruded monolithic blocks of 100 × 100 × 50 mm and 100 × 100 × 100 mm across three adsorption grades (Iodine 400 / 600 / 800 mg/g) and channel pitches from 1.5 mm to 8.0 mm. Dispatched directly from our two Ho Chi Minh City warehouses (District 12 and Nhi Binh), every batch includes CO/CQ documentation, VAT invoices, and technical engineering support for spray booths, printing lines, and industrial odour towers.
Xuyen Viet Environmental Co., Ltd. (Công ty TNHH Môi Trường Xuyên Việt — Tax ID `0310866342`) is a specialized industrial distributor and environmental engineering supplier of honeycomb activated carbon in Vietnam. Designed for high-airflow exhaust systems where granular or extruded pelletized beds cause excessive fan static pressure loss, monolithic honeycomb activated carbon vietnam blocks deliver low pressure drop (ΔP), uniform airflow distribution, and fast modular cassette replacement in manufacturing zones nationwide.

1. Technical Specifications — Honeycomb Activated Carbon 100×100×50mm & 100×100×100mm
When specifying honeycomb activated carbon vietnam for environmental systems, selecting the correct combination of block thickness (`50 mm` vs `100 mm`), cell channel size (`1.5 mm` up to `8.0 mm`), and Iodine adsorption value (`400`, `600`, or `800 mg/g`) allows plant engineers to balance gas residence time against blower power consumption.
| Parameter | 100 × 100 × 50 mm Block | 100 × 100 × 100 mm Block | Notes / Engineering Reference |
|---|---|---|---|
| External Dimensions (L × W × H) | 100 × 100 × 50 mm | 100 × 100 × 100 mm | 100 blocks/m² face area per single layer |
| Channel Pitch / Hole Size | 1.5 mm standard | 1.5 mm, 3.0 mm, 5.0 mm, 8.0 mm | Smaller pitch = higher contact area; larger pitch = lower dust clogging |
| Iodine Adsorption Grades | 400 / 600 / 800 mg/g | 400 / 600 / 800 mg/g | ASTM D4607 standard test grade options |
| Moisture Content (As Packed) | ≤ 5% – 8% | ≤ 5% – 8% | Moisture-barrier carton packaging |
| Recommended Face Velocity | 0.5 – 1.2 m/s | 0.8 – 1.5 m/s | Higher residence time achieved via 100 mm depth or multi-layer stacking |
| Water-Resistant Grade Option | Available on order | Hydrophobic (Waterproof) available | Required after wet scrubbers / water-curtain spray booths (> 80% RH) |
For Vietnamese documentation on high-humidity hydrophobic blocks, refer to our engineering guide on Than tổ ong chịu nước 100×100×100mm lọc khí buồng sơn.
2. Standard Warehouse SKU Reference Matrix (Standard & Hydrophobic Series)
To streamline RFQ preparation for foreign-invested factories (Japan, Korea, Taiwan, Europe) operating in Vietnam, below is the exact SKU mapping stocked in our inventory system:
| Product Code Series | Block Size | Channel Pitch | Iodine Rating | Primary Suitability |
|---|---|---|---|---|
TTO5400 / TTO5600 / TTO5800 | 100 × 100 × 50 mm | 1.5 mm | 400 / 600 / 800 mg/g | Compact HVAC filter cassettes, thin drawer frames, kitchen & lab vents |
TTO400 / TTO600 / TTO800 | 100 × 100 × 100 mm | 1.5 mm | 400 / 600 / 800 mg/g | High-efficiency VOC & solvent vapour adsorption (Toluene, Xylene, MEK) |
TTO3M400 / TTO3M600 / TTO3800 | 100 × 100 × 100 mm | 3.0 mm | 400 / 600 / 800 mg/g | Balanced pressure drop & particulate tolerance for furniture spray booths |
TTO5M400 / TTO5M600 / TTO8M400 | 100 × 100 × 100 mm | 5.0 mm / 8.0 mm | 400 / 600 mg/g | High-flow exhaust fans requiring ultra-low blower static pressure loss |

3. Industrial Applications Across Vietnam Manufacturing Parks
3.1 Paint Booths, Furniture Finishing & Powder Coating Exhaust
Spray painting lines in wood furniture, automotive components, and metal fabrication plants generate continuous solvent vapours (Toluene, Xylene, Acetone, Butyl Acetate) alongside fine overspray mist. Honeycomb blocks arranged in sliding metal drawer racks sit downstream of G4/F6 pre-filters, achieving uniform VOC capture without starving spray booth extraction fans of suction static pressure.
3.2 Printing, Packaging & Laminating Lines (Rotogravure / Flexo)
Solvent-based inks and laminating adhesives release Ethyl Acetate, MEK, and IPA fumes inside enclosed press rooms. High-iodine (`800 mg/g`) 100×100×100mm blocks stacked in 2 – 4 sequential layers ensure adequate gas contact residence time before exhaust discharge under QCVN 19:2009/BTNMT and QCVN 20:2009/BTNMT.
3.3 Wastewater Treatment Odour Covers & Chemical Vent Scrubbers
Covered equalization tanks, sludge dewatering rooms, and chemical mixing tanks emit hydrogen sulfide (H₂S), ammonia (NH₃), and mercaptans. When located after wet chemical scrubbers where relative humidity exceeds 80%, hydrophobic (water-resistant) honeycomb blocks prevent structural softening and channeling.
3.4 Cleanroom HVAC & Electronics Assembly Make-Up Air
Trace volatile organic acids and ambient industrial odours enter air-handling units (AHUs) near heavy industrial zones such as VSIP, Song Than, Amata, and Long Thanh. Thin 100 × 100 × 50 mm blocks (`TTO5600` / `TTO5800`) integrate cleanly into standard HVAC V-bank and cassette housings where duct depth is constrained.
4. Engineering Guide: How to Calculate Block Quantity & Pressure Drop
Before issuing a purchase order, confirm three geometric parameters inside your adsorption tower or cassette chamber:
- Cross-sectional Face Area (`A_face` in m²): Match the exhaust airflow (`Q` in m³/s) divided by target face velocity (`v = 0.8 – 1.2 m/s`).
- Example: An exhaust fan rated at `10,800 m³/h` (`= 3.0 m³/s`) operating at `1.0 m/s` face velocity requires `A_face = 3.0 m²` (e.g., `2.0 m × 1.5 m` filter bank).
- Blocks per Layer: Because each block measures `0.1 m × 0.1 m = 0.01 m²` on its front face, each single layer requires exactly 100 blocks per m² of cross-section (`3.0 m² × 100 = 300 blocks per layer`).
- Number of Sequential Layers (Bed Depth):
- Low-odour ventilation / HVAC cassettes: 1 to 2 layers of `100×100×50mm` blocks (50 – 100 mm bed depth).
- Industrial solvent paint booths & VOC towers: 3 to 6 layers of `100×100×100mm` blocks (300 – 600 mm total depth) with intermediate spacer seals to stop edge bypass leakage.
Engineers seeking full blower sizing equations and bed residence time calculations can review our detailed Vietnamese design manual: Hướng dẫn tính toán tháp hấp thụ than hoạt tính chuẩn kỹ thuật or convert mesh particle screens using the Mesh to Micron & mm Conversion Tool.
B2B Wholesale Quotation Policy: Block pricing varies according to Iodine grade (400 / 600 / 800 mg/g), dimensions (50mm vs 100mm), hydrophobic treatment, order volume, VAT, and delivery distance to your plant. Please contact our Engineering Sales Hotline at +84-903-018-135 (Zalo / Phone) for an official project quotation, real-time stock confirmation, and CO/CQ dossier.
5. Quality Verification & Pre-Installation Checklist for Plant Engineers
- Pre-filtration protection: Always install dry particulate pre-filters (e.g., fiberglass paint arrestor + G4/F6 pocket filter) upstream of honeycomb carbon blocks. Airborne oil mist or uncured paint droplets coat carbon micropores and rapidly exhaust adsorption life regardless of Iodine grade.
- Perimeter gasket sealing: Place closed-cell EPDM or neoprene foam strips along steel tray edges so exhaust gas passes through the honeycomb channels rather than leaking around frame gaps.
- Moisture control: Store spare cartons raised off concrete floors on wooden/plastic pallets in dry indoor storage before installation. Avoid exposing non-hydrophobic grades directly to saturated mist or rain droplets.
6. Frequently Asked Questions (FAQ) — Honeycomb Activated Carbon Vietnam
When should engineers choose 100x100x50mm blocks vs 100x100x100mm blocks?
Choose 100x100x50mm blocks when retrofitting shallow HVAC cassette frames, thin kitchen/lab fume hoods, or limited duct clearances. Choose 100x100x100mm blocks for multi-layer industrial VOC adsorption towers, paint booths, and solvent exhaust systems requiring longer gas contact time and fewer handling pieces during replacement.
How many honeycomb carbon blocks are required per square meter of filter face area?
Since both standard block sizes share a 100 mm × 100 mm front face (0.01 m²), one single layer strictly requires 100 blocks per square meter of active filter cross-section, multiplied by the number of depth layers in your rack.
Does Xuyen Viet Environmental supply VAT invoices and CO/CQ documents for FDI factories in Vietnam?
Yes. Xuyen Viet Environmental Co., Ltd. issues full Vietnamese electronic VAT invoices along with batch CO/CQ and MSDS documentation from our warehouses in Ho Chi Minh City, serving Song Than, VSIP Binh Duong, Amata Dong Nai, Long An, and nationwide industrial zones.
7. Contact Xuyen Viet Environmental Co., Ltd.
- Company: Công ty TNHH Môi Trường Xuyên Việt (Xuyen Viet Environmental Co., Ltd. — MST `0310866342`)
- Engineering Hotline (Phone / Zalo): +84-903-018-135 (`0903.018.135`)
- Trụ sở chính: 537/18/4 Nguyễn Oanh, Phường 17, Quận Gò Vấp, TP.HCM
- Hệ thống kho hàng & nhà máy: Tổng kho Miền Nam (Quận 12 & Hóc Môn), Tổng kho Miền Bắc (Hà Nội) và Nhà máy sản xuất than gáo dừa Bến Tre
- Warehouse 1: 11A TL43 St., Thanh Loc Ward, District 12, Ho Chi Minh City
- Warehouse 2: Nhi Binh 19 St., Dong Thanh, Ho Chi Minh City
- Email (RFQ & Tender Documents): `moitruongxuyenviet@gmail.com`
Related guides: Báo giá than hoạt tính sỉ tại kho tổng • Cung cấp than hoạt tính tại KCN Sóng Thần – Dĩ An • Than hoạt tính tổ ong lọc khí khử mùi

Than Hoạt Tính Tổ Ong Xử Lý Khí Thải Công Nghiệp [Báo Giá Sỉ Kho 2026]
Khối 100×100×100mm & 100×100×50mm • Benzen ≥ 32% • Hấp phụ VOCs buồng sơn
Than Hoạt Tính Tổ Ong Lọc Khí - Khử Mùi Công Nghiệp (Kháng Nước)
Dòng chịu nước chống rã ngâm 48h • Trở lực thấp ΔP < 250 Pa • Thùng 18/36 viên
Quý Nhà Thầu & Doanh Nghiệp Cần Tính Toán Số Khối Than Nạp Tháp Khí?
Đội ngũ kỹ sư Môi Trường Xuyên Việt hỗ trợ thẩm định lưu lượng quạt hút, tính toán vận tốc gió mặt v = 0.8 - 1.2 m/s và lập bảng báo giá sỉ tại tổng kho Q.12 & Dĩ An.